You are here:

RowCool InRow Precision Cooling Systems

The Deckro RowCool Series delivers 12.5–62.7 kW of precision cooling for modular data centers, high-density server rooms and mission-critical IT infrastructure. Featuring DC inverter compressors, EC fans and flexible 300 mm / 600 mm cabinet widths, the series is available in 1100 mm, 1200 mm and 1400 mm depth configurations. Cooling-only and temperature-and-humidity solutions are offered according to model requirements.

12.5–62.7 kW Cooling
300 / 600 mm Width
1100 / 1200 / 1400 mm Depth
DC Inverter & EC Fans
7-Inch Touchscreen (25–60 kW)
Air-Cooled Precision Cooling

Product Number : DRC-IR-025
Product Description : RowCool Direct Expansion InRow Cooling 25.5kW

Description

Key Features & Advantages

12.5–62.7 kW Cooling Capacity

Six capacity classes for modular data centers, server rooms and high-density IT environments.

DC Inverter Technology

Variable-frequency compressors adapt cooling output to changing IT heat loads.

EC Fan Technology

Electronically commutated fans support efficient and responsive airflow management.

Three Cabinet Depths

Available in 1100, 1200 and 1400 mm depths for different rack-row layouts.

Intelligent Control

7-inch touchscreen on 25–60 kW models, with monitoring, alarms and group control functions.

Flexible Environmental Control

Cooling-only and temperature-and-humidity configurations, subject to model availability.

Typical Applications

Modular Data Centers

Precision cooling integrated into modular IT infrastructure.

High-Density Server Rooms

Localized cooling for concentrated server and network equipment loads.

Hot & Cold Aisle Layouts

In-row deployment alongside IT cabinets and containment systems.

Edge Data Centers

Cooling infrastructure for distributed and regional IT installations.

Container Data Centers

Configurable cooling for engineered containerized IT solutions.

Mission-Critical Infrastructure

Environmental control for continuously operated IT environments.

Models & Cooling Capacities

Deckro RowCool Series offers six nominal capacity classes with 300 mm and 600 mm cabinet widths. Each capacity class is available with 1100, 1200 or 1400 mm cabinet depth options.

Model Series Cooling Capacity Cabinet Width Airflow Available Depths
DRC-IR-012 12.5 kW 300 mm 2,850 m³/h* 1100 / 1200 / 1400 mm
DRC-IR-025 25.5 kW 300 mm 5,080 m³/h* 1100 / 1200 / 1400 mm
DRC-IR-030 30.8 kW 300 mm 5,250 m³/h* 1100 / 1200 / 1400 mm
DRC-IR-040 42.8 kW 600 mm 8,580 m³/h* 1100 / 1200 / 1400 mm
DRC-IR-050 51.5 kW 600 mm 10,600 m³/h* 1100 / 1200 / 1400 mm
DRC-IR-060 62.7 kW 600 mm 11,600 m³/h* 1100 / 1200 / 1400 mm

*Airflow figures are taken from the product-family technical reference. Performance for each cabinet-depth variant is subject to final technical confirmation.

6

Capacity Classes

3

Depth Options

36

Indoor Configurations

Technical Specifications

Cooling Technology

  • Air-cooled precision cooling
  • DC variable-frequency compressor
  • EC fan technology
  • Electronic expansion valve
  • R410A refrigerant
  • Variable-capacity operation

Mechanical Configuration

  • 300 mm width: 12 / 25 / 30 kW classes
  • 600 mm width: 40 / 50 / 60 kW classes
  • Depth options: 1100 / 1200 / 1400 mm
  • Nominal cabinet height: 2000 mm
  • Dual-side supply: 12 kW class
  • Front supply: 25–60 kW classes

Control & Monitoring

  • 7-inch color touchscreen: 25–60 kW
  • 12 kW configuration: without display
  • Real-time operating information
  • Alarm and parameter management
  • Multi-unit group control functionality
  • Project-specific integration requirements

Environmental Configuration

  • Cooling-only configuration
  • Constant temperature and humidity option
  • Electric reheating on equipped models
  • Humidification: 3 kg/h where equipped
  • Standard outdoor condensing units
  • Engineered centralized outdoor solutions

Electrical & Environmental Data

Model Reheat Humidifier Cooling FLA* Temp. & Humidity FLA*
DRC-IR-012 3.0 kW 3.0 kg/h 19.0 A 22.9 A
DRC-IR-025 4.5 kW 3.0 kg/h 23.2 A 27.9 A
DRC-IR-030 4.5 kW 3.0 kg/h 29.2 A 34.0 A
DRC-IR-040 6.0 kW 3.0 kg/h 30.1 A 37.6 A
DRC-IR-050 6.5 kW 3.0 kg/h 34.8 A 42.0 A
DRC-IR-060 6.5 kW 3.0 kg/h 43.8 A 51.0 A

*Electrical current values are based on the technical reference and must be verified against the selected configuration before electrical design. Reference supply: 380 V, three-phase with neutral, 50 Hz. Final voltage and frequency compatibility must be confirmed per model.

Outdoor Unit Configurations

Deckro RowCool systems can be supplied with standard outdoor condensing units or project-engineered centralized outdoor configurations.

Standard Outdoor Units

Deckro Code Indoor Model Fans Net Weight W × D × H (mm)
DRC-ODU-020-S DRC-IR-012 2 49 kg 832 × 330 × 1246*
DRC-ODU-040-S DRC-IR-025 1 135 kg 1378 × 982 × 740
DRC-ODU-046-S DRC-IR-030 1 139 kg 1578 × 1275 × 750
DRC-ODU-058-S DRC-IR-040 1 150 kg 1778 × 1275 × 750
DRC-ODU-078-S DRC-IR-050 2 176 kg 2178 × 1275 × 740
DRC-ODU-090-S DRC-IR-060 2 185 kg 2378 × 1275 × 750

*The 12 kW outdoor-unit dimensions differ between source documents. All outdoor dimensions and weights require confirmation against the final approved drawings.

Centralized Outdoor Units

Deckro Code Fans Net Weight W × D × H (mm)
DRC-ODU-046-C 1 140 kg 1098 × 1098 × 1684
DRC-ODU-058-C 1 150 kg 1098 × 1098 × 1684
DRC-ODU-068-C 1 166 kg 1098 × 1098 × 1774
DRC-ODU-078-C 1 176 kg 1098 × 1098 × 1774
DRC-ODU-090-C 1 186 kg 1298 × 1098 × 1774
DRC-ODU-098-C 1 196 kg 1298 × 1098 × 1774

Centralized outdoor units are not assigned on a one-to-one basis. Selection, refrigerant piping and system compatibility require project-specific engineering verification.

Optional Accessories & Configurations

Condensate Pump Kit

Code: DRC-ACC-CP100

5 m lift head. Available with compatible in-row cooling units.

Negative-Head Kit

Code: DRC-ACC-NH200

For applications requiring negative-head compensation above 5 m and below 10 m.

Extension Kit

Code: DRC-ACC-EX300

For refrigerant piping exceeding the standard length limit. Applicable to 25–60 kW models, subject to design verification.

Low-Ambient Kit

Code: DRC-ACC-LT300

For outdoor ambient temperatures below -20°C. Available for compatible 25–60 kW configurations.

Energy-Saving Module

Code: DRC-ACC-ES200

Variable-frequency free-cooling accessory for engineered 60 kW applications. Dual-system configurations require two modules, subject to engineering confirmation.

Product Codes & Ordering Information

Indoor unit codes identify cooling capacity, environmental configuration and cabinet depth.

DRC-IR-025-H-D12

Deckro RowCool / 25 kW Class / Temperature & Humidity / 1200 mm Depth

Capacity Class Temperature & Humidity Cooling Configuration*
12 kW DRC-IR-012-H-D11 / D12 / D14 DRC-IR-012-C-D11 / D12 / D14
25 kW DRC-IR-025-H-D11 / D12 / D14 DRC-IR-025-C-D11 / D12 / D14
30 kW DRC-IR-030-H-D11 / D12 / D14 DRC-IR-030-C-D11 / D12 / D14
40 kW DRC-IR-040-H-D11 / D12 / D14 DRC-IR-040-C-D11 / D12 / D14
50 kW DRC-IR-050-H-D11 / D12 / D14 DRC-IR-050-C-D11 / D12 / D14
60 kW DRC-IR-060-H-D11 / D12 / D14 DRC-IR-060-C-D11 / D12 / D14

D11 = 1100 mm; D12 = 1200 mm; D14 = 1400 mm.
H = constant temperature and humidity.
C = cooling configuration.
*The 12 kW C configuration requires final confirmation of its temperature-control functions.

Standard outdoor unit codes: DRC-ODU-020-S, DRC-ODU-040-S, DRC-ODU-046-S, DRC-ODU-058-S, DRC-ODU-078-S and DRC-ODU-090-S.

Centralized outdoor unit codes: DRC-ODU-046-C, DRC-ODU-058-C, DRC-ODU-068-C, DRC-ODU-078-C, DRC-ODU-090-C and DRC-ODU-098-C.

Engineering & Project Integration

Deckro RowCool systems are selected according to the project cooling load, rack arrangement, airflow direction, outdoor ambient conditions and refrigerant piping requirements.

Final equipment dimensions, electrical characteristics, outdoor unit selection, operating conditions and configuration-specific performance must be confirmed through the approved technical documentation before ordering.

Configure Your Deckro RowCool Solution

Contact Deckro for model selection, cabinet depth options, outdoor unit configuration, technical documentation and project-specific quotations.