Description
Key Features & Advantages
Fully Integrated Container
All electrical, mechanical and environmental systems integrated inside a standard 20FT ISO High Cube structure.
Scalable UPS Capacity
300 / 400 / 500 kVA options with 2N or N+1 redundancy configurations.
High Efficiency
Up to 95% AC-AC efficiency and grid-friendly input power factor up to 0.99.
Long Autonomy
Battery system supports 15–90 minutes autonomy with up to 480 batteries (VRLA or LFP).
Harsh Environment Ready
IP55 protection, C4-H corrosion resistance and -25°C to +55°C operating range.
Plug & Play Deployment
Factory-tested delivery with minimal on-site assembly for rapid commissioning.
Typical Applications
Telecommunications
Reliable power support for uninterrupted communication infrastructure.
Energy Distribution
Guaranteed continuous operation in critical energy systems.
Industrial Control
Uninterrupted power continuity in production lines and automation infrastructures.
Railway & Transportation
Safe energy management in transportation and railway systems.
Renewable Energy
Integrated solutions for clean energy systems.
Defense & Outdoor ICT
Reliable power infrastructure in harsh and remote conditions.
Models & Configurations
PowerCore series is supplied in 2N or N+1 redundancy configurations with the following UPS capacity options.
| Model | UPS Model | Power (kVA/kW) | Total Capacity | Redundancy |
|---|---|---|---|---|
| PowerCore20/300 | 3300H | 300 / 300 | 600 kVA | 2N / N+1 |
| PowerCore20/400 | 3400H | 400 / 400 | 800 kVA | 2N / N+1 |
| PowerCore20/500 | 3500H | 500 / 500 | 1000 kVA | 2N / N+1 |
3
Model options: 300 / 400 / 500 kVA
480
Maximum battery capacity (cells/units as configured)
90 min
Autonomy (depending on configuration)
Container Structure & Physical Specs
- 20FT ISO High Cube container
- External dimensions: 6058 × 2438 × 2896 mm
- Body: 2 mm galvanized steel
- Insulation: 60 mm sandwich panel
- Equipped weight: 11–12 tons
- Floor bearing capacity: 1500 kg/m²
- Protection class: IP55
- C4-H corrosion resistance (ISO 9227)
- Operating temperature: -25°C to +55°C
- Design life: ≥25 years
Access, Cable Entries & Standard Equipment
- Rear double-wing main door + side service door
- Multi-point locking system with EPDM gasket sealing
- IP-protected multi-cable channels with brush & gland base entry
- Industrial LED lighting, service socket, emergency lamp
- Earthing bar and maintenance area markings (standard)
UPS System (DS Power H Series)
- Topology: Transformerless Online Double Conversion (VFI)
- 3-Level IGBT + DSP controlled fully digital structure
- Parallel operation: up to 8 systems
- Input: 380/400 VAC ±20%, PF ≥0.99, THDi ≤3%, generator compatible
- Output: 380/400 VAC ±1%, pure sine wave, THD ≤2% (linear load), crest factor 3:1
- Efficiency: up to 95% (AC-AC)
Battery, Cooling, Fire & Monitoring
- Battery: VRLA (AGM/Gel) or LFP (LiFePO4), scalable 15–90 min autonomy
- Max batteries: up to 480; nominal DC: 2 × 405 VDC (EOD: 2 × 300 VDC)
- Cooling: industrial cabinet AC, 2 units in N+1 redundancy, total 10–14 kW
- Fire suppression: Novec 1230 or FM-200, EN 12094-1 control, EN 54 detectors
- Monitoring: web-based software + local TFT, SNMP/Modbus TCP/IP, event logs & reporting
Electrical Distribution & Grounding
Power Distribution Panel
IP55 metal enclosure, 4-pole MCCB main switch, 50 kA breaking capacity. Separate circuits for UPS, AC, lighting and fire systems.
Protection Equipment
MCCB/MCB/RCD, Type 2 SPD (40 kA), LSZH flame-retardant cabling and digital energy analyzer monitoring.
Grounding System
TN-S system with separate PE/N lines. Copper busbar (Cu 25×3 mm), equipotential bonding and target ground resistance ≤1Ω.
Standards & Certifications
UPS & Power Systems: IEC/EN 62040-1/2/3, IEC/EN 60950-1, IEC/EN 61000-6-2/6-4
Battery: IEC/EN 60896-21/22, IEC 62619, UL 1989, UN 38.3
Fire Safety: EN 12094-1, EN 54 series, ISO 14520-1
Electrical: IEC/EN 61439-1/2, IEC/EN 60364-4-41, EN 50522, IEC/EN 61643-11
Mechanical/Container: ISO 668, ISO 1496-1, IEC 60068-2-6/14/30, EN ISO 12944-6, ISO 9227 / ASTM B117
Management: ISO 9001:2015, ISO 14001:2015, ISO 45001:2018, CE Mark
Test & Approval: FAT, SAT, TSE, GOST-R
Battery: IEC/EN 60896-21/22, IEC 62619, UL 1989, UN 38.3
Fire Safety: EN 12094-1, EN 54 series, ISO 14520-1
Electrical: IEC/EN 61439-1/2, IEC/EN 60364-4-41, EN 50522, IEC/EN 61643-11
Mechanical/Container: ISO 668, ISO 1496-1, IEC 60068-2-6/14/30, EN ISO 12944-6, ISO 9227 / ASTM B117
Management: ISO 9001:2015, ISO 14001:2015, ISO 45001:2018, CE Mark
Test & Approval: FAT, SAT, TSE, GOST-R
Product Codes
| Stock Code | Product Description | Capacity | Redundancy | Battery |
|---|---|---|---|---|
| PC20-300S | PowerCore 20FT / 300 kVA 3 Standard | 300 kVA | N | 480 |
| PC20-300R | PowerCore 20FT / 300 kVA 3 Redundant | 300 kVA | N+1 | 480 |
| PC20-400S | PowerCore 20FT / 400 kVA 3 Standard | 400 kVA | N | 480 |
| PC20-400R | PowerCore 20FT / 400 kVA 3 Redundant | 400 kVA | N+1 | 480 |