You are here:

PowerOne RT Online UPS 2kVA

True online double conversion (VFI) UPS designed for uninterrupted power protection in data centers, telecom, network rooms, industrial control and mission-critical IT infrastructures. Rack/Tower convertible design, PF=1.0 output and advanced monitoring options ensure maximum continuity and control.

1–10 kVA
Online VFI (Double Conversion)Rack / Tower
Hot-Swap Batteries
110–288 Vac Input Range
Product Number : DPO-003-SI9P
Product Description : Deckro PowerOne Pro Online UPS 3kVA / 3kW, PF=1, Internal Battery (6×12V 9Ah)

Description

Key Features & Advantages

True Online Double Conversion
DSP-controlled UPS with 3-Level topology for stable, clean output power in critical loads.
1.0 Output Power Factor
PF=1.0 output for maximum usable kW capacity and better load compatibility.
High Efficiency
Up to 94.5% efficiency (typ.) and up to 98% in ECO mode for reduced operating cost.
Wide Input Range
110–288 Vac input voltage range and 40–70 Hz frequency range, generator friendly.
Smart Battery Management
Hot-swap battery support, intelligent charging and configurable battery count (16–20).
Flexible Installation
Rack & Tower usage flexibility with LCD+LED user interface and multiple comm. options.

Typical Applications

Data Centers & IT Rooms
Servers, network, storage, security appliances, edge IT and comms.
Telecommunications
Transmission rooms, base stations, NOC rooms, small shelters.
Hospitals & Healthcare
Critical electronics, labs, imaging support and building ICT.
Banks & Financial Institutions
Branch IT continuity, network rooms and secure operations.
Industrial Facilities
Automation, control panels, instrumentation and process IT.
Offices & Business Centers
Core network, small server rooms, security systems and AV.

Models & Configurations

Deckro PowerOne RT Series covers 1–10 kVA capacity range with rack/tower flexibility and optional long-run battery configurations.

Model Capacity Input Output Battery (DC)
PowerOne+ 101RT 1 kVA 208/220/230/240 Vac, PF 0.99, THDi ≤ 5% Sine wave, PF 1.0, THD ≤ 1% (linear) 192 Vdc (adj. 192–240), 16–20 batteries
PowerOne+ 103RT 3 kVA 110–288 Vac range, 40–70 Hz ±1% regulation, crest factor 3:1 192 Vdc (adj. 192–240), 16–20 batteries
PowerOne+ 105RT 5 kVA Bypass range -40% ~ +15% (adjustable) Overload up to 150% (short duration) 192 Vdc (adj. 192–240), 16–20 batteries
PowerOne+ 106RT 6 kVA Single phase input, APFC up to 0.99 50/60Hz ±0.1% in battery mode 192 Vdc (adj. 192–240), 16–20 batteries
PowerOne+ 110RT 10 kVA Wide input range, generator compatible Sine wave, PF 1.0, THD ≤ 4% (non-linear) 192 Vdc (adj. 192–240), 16–20 batteries
1–10
kVA capacity range
0 ms
transfer time (online)
4
parallel connections (max)

Input Specifications

  • Input wiring: 1F – 3 wire (F + N + T)
  • Nominal voltage: 208 / 220 / 230 / 240 Vac
  • Voltage range: 110–176 Vac (linear derating 50–100% load); 176–288 Vac (no derating)
  • Frequency: 50/60 Hz auto sensing
  • Frequency range: 40–70 Hz
  • Input PF: up to 0.99
  • THDi: ≤ 5%
  • Bypass voltage range: -40% ~ +15% (adjustable)

Output Specifications

  • Output wiring: Single phase (F – N)
  • Output voltage: 208 (PF=0.9) / 220 / 230 / 240 Vac
  • Voltage regulation: ±1%
  • Frequency: synchronized to bypass (mains); 50/60 Hz ±0.1% (battery)
  • Waveform: Sine wave
  • Output PF: 1.0
  • THD: ≤ 1% (linear); ≤ 4% (non-linear)
  • Crest factor: 3:1
  • Overload: 105–110% / 10 min, 110–125% / 1 min, 126–150% / 30 sec

Battery & Charging

  • DC voltage: 192 Vdc (adjustable 192–240 Vdc)
  • Battery count: 16 units (adjustable 16–20)
  • Hot-swap battery support
  • Charging current: Standard model 1A; Long-run 5A (default) adjustable 1–5A; optional up to 12A
  • Charging time: Standard 90% in ~8 hours; long-run depends on external battery
  • Smart charging: float/equalization control, charger sleep control (battery life improvement)

System & Environment

  • Transfer time: 0 ms
  • Protections: short circuit, overload, over temperature, battery low/over/under voltage, fan failure
  • Parallel connections: up to 4
  • Communication: RS232 (standard); optional USB / RS485 / dry contacts / SNMP / battery temp comp.
  • Display: LCD + LED
  • Operating temperature: 0°C ~ 40°C
  • Storage temperature: -25°C ~ 55°C (without battery)
  • Humidity: 0 ~ 95% (non-condensing), IP class: IP20
  • Altitude: ≤1000 m (1% derating per additional 100 m)

Optional Configurations

Parallel Function
Optional parallel configuration for increased capacity and redundancy (up to 4).
Communication Cards
SNMP, USB, RS485, dry contacts and smart slot options for monitoring.
Battery Temperature Compensation
Battery temperature compensation for improved battery performance and lifetime.
Long-Run Battery System
External battery cabinet integration and adjustable charge current/voltage according to autonomy needs.
Environmental Monitoring
EMD and SMS alarms for critical room monitoring (as option).

Product Codes

Model Code Product Description Capacity Form Factor Battery Type
PowerOne+ 101RT Online UPS, DSP + 3-Level, PF=1.0, Rack/Tower 1 kVA Rack/Tower Internal (standard) / External (long-run)
PowerOne+ 103RT Online UPS, wide input range, hot-swap support 3 kVA Rack/Tower Internal (standard) / External (long-run)
PowerOne+ 105RT Online UPS, PF=1.0 output, ECO mode up to 98% 5 kVA Rack/Tower Internal (standard) / External (long-run)
PowerOne+ 106RT Online UPS, strong overload capability, multiple interfaces 6 kVA Rack/Tower Internal (standard) / External (long-run)
PowerOne+ 110RT Online UPS, max performance for IT and data center loads 10 kVA Rack/Tower Internal (standard) / External (long-run)

Note: Standard vs Long-run model options depend on battery configuration and charger rating.

Need a reliable UPS for your critical IT infrastructure?
Share your load (kVA/kW), autonomy expectation, installation type (rack/tower) and monitoring needs — we’ll recommend the right PowerOne RT model.