Beschreibung
Wichtige Merkmale & Vorteile
Typische Anwendungen
Models & Configurations
Deckro RackCool Series is available in split-type and integrated configurations for different rack cooling requirements, equipment loads and installation environments.
| Model | Configuration | Cooling Capacity | Rack Height | Air Volume |
|---|---|---|---|---|
| DRC-035-S | Split Type | 3.5 kW | 4U | 700 m³/h |
| DRC-075-S | Split Type | 7.5 kW | 8U | 1,500 m³/h |
| DRC-125-S | Split Type | 12.5 kW | 10U | 2,300 m³/h |
| DRC-035-I | Integrated | 3.5 kW | 8U | 700 m³/h |
Cooling Technology & Performance
- Nominal cooling capacity: 3.5 / 7.5 / 12.5 kW
- Close-coupled rack-mounted precision cooling
- DC inverter compressor technology
- Electronic expansion valve
- High-efficiency EC fan
- V-shaped evaporator construction
- Refrigerant: R410A
- Specified sensible heat ratio: 100%
Indoor Unit & Physical Specifications
- DRC-035-S: 483 × 750 × 175 mm; 22 kg
- DRC-075-S: 483 × 750 × 353 mm; 38 kg
- DRC-125-S: 483 × 800 × 442 mm; 47 kg
- DRC-035-I: 440 × 900 × 355 mm; 45 kg
- Airflow: 700 / 1,500 / 2,300 m³/h
- Rack-mounted pull-out design
- Split and integrated configurations
Power Supply, Heating & Humidification
- Power supply: 220 V AC, single-phase, 50 Hz
- Maximum operating current: 13.5 / 26.8 / 30.5 A
- PTC heating: 1.2 / 2.4 / 3.0 kW
- Optional humidification for split models
- Humidification capacity: 0.6 / 1.2 / 1.5 kg/h
- Integrated 3.5 kW model: humidification not specified
- Automatic restart after power restoration
Outdoor Units & Installation
- DRC-035-S outdoor unit: 898 × 340 × 606 mm; 35 kg
- DRC-075-S outdoor unit: 935 × 396 × 800 mm; 45 kg
- DRC-125-S outdoor unit: 988 × 440 × 1257 mm; 65 kg
- Outdoor unit full-load current: 7.2 / 14.8 / 18.0 A
- Outdoor unit power: 220 V AC, single-phase, 50 Hz
- Specified outdoor operating range: -15°C to +45°C*
- Integrated model: no separate outdoor unit
Cooling & Airflow Management
Standards & Certifications
Electrical & Safety Compliance: Applicable conformity documents and certification status to be confirmed for the selected model and destination market.
Factory Testing: Inspection and test documentation subject to the agreed project scope.
Installation Requirements: Final selection must consider rack heat load, power supply, unit dimensions, outdoor-unit installation and environmental conditions.
Produktcodes
| Stock Code | Product Description | Capacity | Configuration | Rack Height |
|---|---|---|---|---|
| DRC-035-S | RackCool 3.5 kW Rack-Mounted Precision Cooling | 3.5 kW | Split Type | 4U |
| DRC-075-S | RackCool 7.5 kW Rack-Mounted Precision Cooling | 7.5 kW | Split Type | 8U |
| DRC-125-S | RackCool 12.5 kW Rack-Mounted Precision Cooling | 12.5 kW | Split Type | 10U |
| DRC-035-I | RackCool 3.5 kW Integrated Precision Cooling | 3.5 kW | Integrated | 8U |
*Outdoor operating temperature range and final model-specific performance conditions are subject to technical confirmation.