{"id":99736,"date":"2026-10-30T18:27:16","date_gmt":"2026-10-30T15:27:16","guid":{"rendered":"https:\/\/www.deckro.net\/?post_type=product&#038;p=99736"},"modified":"2026-10-30T18:45:47","modified_gmt":"2026-10-30T15:45:47","slug":"rackcool-precision-cooling-systems-copy","status":"publish","type":"product","link":"https:\/\/www.deckro.net\/es\/producto\/rackcool-precision-cooling-systems-copy\/","title":{"rendered":"Sistemas de refrigeraci\u00f3n de precisi\u00f3n RackCool de 7.5kW"},"content":{"rendered":"<p><!-- DECKRO RACKCOOL SERIES | PRODUCT DESCRIPTION --><\/p>\n<p><!-- KEY FEATURES & ADVANTAGES --><\/p>\n<section class=\"deckro-features\" style=\"padding:22px 0;border-top:1px solid #eee;border-bottom:1px solid #eee;\">\n<div class=\"wrap\" style=\"max-width:1200px;margin:0 auto;padding:0 16px;\">\n<h2 style=\"margin:0 0 14px;font-size:26px;\">Caracter\u00edsticas<\/h2>\n<div style=\"display:grid;grid-template-columns:repeat(3,1fr);gap:14px;\">\n<div style=\"border:1px solid #eee;border-radius:14px;padding:14px;\">\n<div style=\"font-weight:800;\"><span style=\"color:#c1121f;\">Compact Rack-Mounted Design<\/span><\/div>\n<div style=\"opacity:.85;margin-top:6px;\">Space-saving precision cooling units designed for integration into IT racks, server cabinets and compact edge infrastructure.<\/div>\n<\/p><\/div>\n<div style=\"border:1px solid #eee;border-radius:14px;padding:14px;\">\n<div style=\"font-weight:800;\"><span style=\"color:#c1121f;\">Flexible Cooling Capacity<\/span><\/div>\n<div style=\"opacity:.85;margin-top:6px;\">Four split and integrated configurations with nominal cooling capacities of 3.5, 7.5 and 12.5 kW.<\/div>\n<\/p><\/div>\n<div style=\"border:1px solid #eee;border-radius:14px;padding:14px;\">\n<div style=\"font-weight:800;\"><span style=\"color:#c1121f;\">Energy-Efficient Inverter Technology<\/span><\/div>\n<div style=\"opacity:.85;margin-top:6px;\">DC inverter compressor, EC fan and electronic expansion valve provide variable-capacity operation according to the cooling demand.<\/div>\n<\/p><\/div>\n<div style=\"border:1px solid #eee;border-radius:14px;padding:14px;\">\n<div style=\"font-weight:800;\"><span style=\"color:#c1121f;\">Close-Coupled Precision Cooling<\/span><\/div>\n<div style=\"opacity:.85;margin-top:6px;\">Delivers cooling directly inside or near the equipment rack, helping reduce unnecessary room-level airflow and improve thermal management.<\/div>\n<\/p><\/div>\n<div style=\"border:1px solid #eee;border-radius:14px;padding:14px;\">\n<div style=\"font-weight:800;\"><span style=\"color:#c1121f;\">Intelligent Monitoring &#038; Control<\/span><\/div>\n<div style=\"opacity:.85;margin-top:6px;\">Standard RS485 communication interface supports remote monitoring and control in distributed and unattended IT environments.<\/div>\n<\/p><\/div>\n<div style=\"border:1px solid #eee;border-radius:14px;padding:14px;\">\n<div style=\"font-weight:800;\"><span style=\"color:#c1121f;\">Easy Installation &#038; Maintenance<\/span><\/div>\n<div style=\"opacity:.85;margin-top:6px;\">Pull-out rack-mounted construction simplifies installation and servicing, with automatic restart after mains power restoration.<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/section>\n<p><!-- TYPICAL APPLICATIONS --><\/p>\n<section class=\"deckro-apps\" style=\"padding:26px 0;\">\n<div class=\"wrap\" style=\"max-width:1200px;margin:0 auto;padding:0 16px;\">\n<h2 style=\"margin:0 0 14px;font-size:26px;\">Aplicaciones t\u00edpicas<\/h2>\n<div style=\"display:grid;grid-template-columns:repeat(3,1fr);gap:14px;\">\n<div style=\"border-left:4px solid #c00;padding:12px 12px 12px 14px;background:#fafafa;border-radius:12px;\">\n<div style=\"font-weight:800;\">Edge Data Centers<\/div>\n<div style=\"opacity:.85;margin-top:6px;\">Localized precision cooling for compact edge computing and distributed IT infrastructure.<\/div>\n<\/p><\/div>\n<div style=\"border-left:4px solid #c00;padding:12px 12px 12px 14px;background:#fafafa;border-radius:12px;\">\n<div style=\"font-weight:800;\">Single Server Cabinets<\/div>\n<div style=\"opacity:.85;margin-top:6px;\">Dedicated thermal management for individual server racks and equipment cabinets.<\/div>\n<\/p><\/div>\n<div style=\"border-left:4px solid #c00;padding:12px 12px 12px 14px;background:#fafafa;border-radius:12px;\">\n<div style=\"font-weight:800;\">Telecommunications<\/div>\n<div style=\"opacity:.85;margin-top:6px;\">Precision temperature control for network equipment, communication racks and telecom installations.<\/div>\n<\/p><\/div>\n<div style=\"border-left:4px solid #c00;padding:12px 12px 12px 14px;background:#fafafa;border-radius:12px;\">\n<div style=\"font-weight:800;\">Micro Data Centers<\/div>\n<div style=\"opacity:.85;margin-top:6px;\">Rack-integrated cooling for modular micro data center and self-contained IT infrastructure solutions.<\/div>\n<\/p><\/div>\n<div style=\"border-left:4px solid #c00;padding:12px 12px 12px 14px;background:#fafafa;border-radius:12px;\">\n<div style=\"font-weight:800;\">Industrial IT Infrastructure<\/div>\n<div style=\"opacity:.85;margin-top:6px;\">Cooling for critical IT and control equipment installed in space-constrained industrial environments.<\/div>\n<\/p><\/div>\n<div style=\"border-left:4px solid #c00;padding:12px 12px 12px 14px;background:#fafafa;border-radius:12px;\">\n<div style=\"font-weight:800;\">Remote &#038; Unattended Sites<\/div>\n<div style=\"opacity:.85;margin-top:6px;\">Remote monitoring and automatic restart capabilities for distributed equipment locations.<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/section>\n<p><!-- MODELS & CONFIGURATIONS --><\/p>\n<section class=\"deckro-models\" style=\"padding:22px 0;border-top:1px solid #eee;\">\n<div class=\"wrap\" style=\"max-width:1200px;margin:0 auto;padding:0 16px;\">\n<h2 style=\"margin:0 0 12px;font-size:26px;\">Models &#038; Configurations<\/h2>\n<p style=\"margin:0 0 14px;opacity:.85;\">Deckro RackCool Series is available in split-type and integrated configurations for different rack cooling requirements, equipment loads and installation environments.<\/p>\n<div style=\"overflow:auto;border:1px solid #eee;border-radius:14px;\">\n<table style=\"width:100%;border-collapse:collapse;min-width:780px;\">\n<thead>\n<tr style=\"background:#111;color:#fff;\">\n<th style=\"text-align:left;padding:12px;\">Model<\/th>\n<th style=\"text-align:left;padding:12px;\">Configuration<\/th>\n<th style=\"text-align:left;padding:12px;\">Cooling Capacity<\/th>\n<th style=\"text-align:left;padding:12px;\">Rack Height<\/th>\n<th style=\"text-align:left;padding:12px;\">Air Volume<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"border-top:1px solid #eee;\">\n<td style=\"padding:12px;\">DRC-035-S<\/td>\n<td style=\"padding:12px;\">Split Type<\/td>\n<td style=\"padding:12px;\">3.5 kW<\/td>\n<td style=\"padding:12px;\">4U<\/td>\n<td style=\"padding:12px;\">700 m\u00b3\/h<\/td>\n<\/tr>\n<tr style=\"border-top:1px solid #eee;\">\n<td style=\"padding:12px;\">DRC-075-S<\/td>\n<td style=\"padding:12px;\">Split Type<\/td>\n<td style=\"padding:12px;\">7.5 kW<\/td>\n<td style=\"padding:12px;\">8U<\/td>\n<td style=\"padding:12px;\">1,500 m\u00b3\/h<\/td>\n<\/tr>\n<tr style=\"border-top:1px solid #eee;\">\n<td style=\"padding:12px;\">DRC-125-S<\/td>\n<td style=\"padding:12px;\">Split Type<\/td>\n<td style=\"padding:12px;\">12.5 kW<\/td>\n<td style=\"padding:12px;\">10U<\/td>\n<td style=\"padding:12px;\">2,300 m\u00b3\/h<\/td>\n<\/tr>\n<tr style=\"border-top:1px solid #eee;\">\n<td style=\"padding:12px;\">DRC-035-I<\/td>\n<td style=\"padding:12px;\">Integrated<\/td>\n<td style=\"padding:12px;\">3.5 kW<\/td>\n<td style=\"padding:12px;\">8U<\/td>\n<td style=\"padding:12px;\">700 m\u00b3\/h<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<div style=\"display:grid;grid-template-columns:repeat(3,1fr);gap:12px;margin-top:14px;\">\n<div style=\"border:1px solid #eee;border-radius:14px;padding:14px;\">\n<div style=\"font-size:34px;font-weight:900;\">4<\/div>\n<div style=\"opacity:.85;\">Available model configurations<\/div>\n<\/p><\/div>\n<div style=\"border:1px solid #eee;border-radius:14px;padding:14px;\">\n<div style=\"font-size:34px;font-weight:900;\">12.5 kW<\/div>\n<div style=\"opacity:.85;\">Maximum nominal cooling capacity<\/div>\n<\/p><\/div>\n<div style=\"border:1px solid #eee;border-radius:14px;padding:14px;\">\n<div style=\"font-size:34px;font-weight:900;\">10U<\/div>\n<div style=\"opacity:.85;\">Maximum indoor unit rack height<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/section>\n<p><!-- TECHNICAL SPECIFICATIONS --><\/p>\n<section class=\"deckro-specs\" style=\"padding:26px 0;\">\n<div class=\"wrap\" style=\"max-width:1200px;margin:0 auto;padding:0 16px;display:grid;grid-template-columns:1fr 1fr;gap:16px;align-items:start;\">\n<div style=\"border:1px solid #eee;border-radius:14px;padding:16px;\">\n<h3 style=\"margin:0 0 10px;\">Cooling Technology &#038; Performance<\/h3>\n<ul style=\"margin:0;padding-left:18px;line-height:1.6;opacity:.9;\">\n<li>Nominal cooling capacity: 3.5 \/ 7.5 \/ 12.5 kW<\/li>\n<li>Close-coupled rack-mounted precision cooling<\/li>\n<li>DC inverter compressor technology<\/li>\n<li>Electronic expansion valve<\/li>\n<li>High-efficiency EC fan<\/li>\n<li>V-shaped evaporator construction<\/li>\n<li>Refrigerant: R410A<\/li>\n<li>Specified sensible heat ratio: 100%<\/li>\n<\/ul><\/div>\n<div style=\"border:1px solid #eee;border-radius:14px;padding:16px;\">\n<h3 style=\"margin:0 0 10px;\">Indoor Unit &#038; Physical Specifications<\/h3>\n<ul style=\"margin:0;padding-left:18px;line-height:1.6;opacity:.9;\">\n<li>DRC-035-S: 483 \u00d7 750 \u00d7 175 mm; 22 kg<\/li>\n<li>DRC-075-S: 483 \u00d7 750 \u00d7 353 mm; 38 kg<\/li>\n<li>DRC-125-S: 483 \u00d7 800 \u00d7 442 mm; 47 kg<\/li>\n<li>DRC-035-I: 440 \u00d7 900 \u00d7 355 mm; 45 kg<\/li>\n<li>Airflow: 700 \/ 1,500 \/ 2,300 m\u00b3\/h<\/li>\n<li>Rack-mounted pull-out design<\/li>\n<li>Split and integrated configurations<\/li>\n<\/ul><\/div>\n<div style=\"border:1px solid #eee;border-radius:14px;padding:16px;\">\n<h3 style=\"margin:0 0 10px;\">Power Supply, Heating &#038; Humidification<\/h3>\n<ul style=\"margin:0;padding-left:18px;line-height:1.6;opacity:.9;\">\n<li>Power supply: 220 V AC, single-phase, 50 Hz<\/li>\n<li>Maximum operating current: 13.5 \/ 26.8 \/ 30.5 A<\/li>\n<li>PTC heating: 1.2 \/ 2.4 \/ 3.0 kW<\/li>\n<li>Optional humidification for split models<\/li>\n<li>Humidification capacity: 0.6 \/ 1.2 \/ 1.5 kg\/h<\/li>\n<li>Integrated 3.5 kW model: humidification not specified<\/li>\n<li>Automatic restart after power restoration<\/li>\n<\/ul><\/div>\n<div style=\"border:1px solid #eee;border-radius:14px;padding:16px;\">\n<h3 style=\"margin:0 0 10px;\">Outdoor Units &#038; Installation<\/h3>\n<ul style=\"margin:0;padding-left:18px;line-height:1.6;opacity:.9;\">\n<li>DRC-035-S outdoor unit: 898 \u00d7 340 \u00d7 606 mm; 35 kg<\/li>\n<li>DRC-075-S outdoor unit: 935 \u00d7 396 \u00d7 800 mm; 45 kg<\/li>\n<li>DRC-125-S outdoor unit: 988 \u00d7 440 \u00d7 1257 mm; 65 kg<\/li>\n<li>Outdoor unit full-load current: 7.2 \/ 14.8 \/ 18.0 A<\/li>\n<li>Outdoor unit power: 220 V AC, single-phase, 50 Hz<\/li>\n<li>Specified outdoor operating range: -15\u00b0C to +45\u00b0C*<\/li>\n<li>Integrated model: no separate outdoor unit<\/li>\n<\/ul><\/div>\n<\/p><\/div>\n<\/section>\n<p><!-- COOLING & AIRFLOW MANAGEMENT --><\/p>\n<section class=\"deckro-electrical\" style=\"padding:22px 0;border-top:1px solid #eee;\">\n<div class=\"wrap\" style=\"max-width:1200px;margin:0 auto;padding:0 16px;\">\n<h2 style=\"margin:0 0 12px;font-size:26px;\">Cooling &#038; Airflow Management<\/h2>\n<div style=\"display:grid;grid-template-columns:repeat(3,1fr);gap:14px;\">\n<div style=\"background:#fafafa;border:1px solid #eee;border-radius:14px;padding:14px;\">\n<div style=\"font-weight:800;\">Close-Coupled Cooling<\/div>\n<div style=\"opacity:.85;margin-top:8px;\">Rack-level cooling arrangement delivers conditioned air close to the equipment heat source, reducing dependence on room-level airflow distribution.<\/div>\n<\/p><\/div>\n<div style=\"background:#fafafa;border:1px solid #eee;border-radius:14px;padding:14px;\">\n<div style=\"font-weight:800;\">Variable-Capacity Operation<\/div>\n<div style=\"opacity:.85;margin-top:8px;\">DC inverter compressor, EC fan and electronic expansion valve continuously adjust system operation to the actual cooling requirement.<\/div>\n<\/p><\/div>\n<div style=\"background:#fafafa;border:1px solid #eee;border-radius:14px;padding:14px;\">\n<div style=\"font-weight:800;\">Remote Monitoring &#038; Control<\/div>\n<div style=\"opacity:.85;margin-top:8px;\">Standard RS485 communication interface enables remote supervision and control for distributed racks and unattended IT installations.<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/section>\n<p><!-- STANDARDS & CERTIFICATIONS --><\/p>\n<section class=\"deckro-standards\" style=\"padding:26px 0;\">\n<div class=\"wrap\" style=\"max-width:1200px;margin:0 auto;padding:0 16px;\">\n<h2 style=\"margin:0 0 12px;font-size:26px;\">Standards &#038; Certifications<\/h2>\n<div style=\"border:1px solid #eee;border-radius:14px;padding:16px;line-height:1.7;opacity:.92;\"><strong>Product Documentation:<\/strong> Technical specifications and configuration details are available upon request.<br \/>\n<strong>Electrical &#038; Safety Compliance:<\/strong> Applicable conformity documents and certification status to be confirmed for the selected model and destination market.<br \/>\n<strong>Factory Testing:<\/strong> Inspection and test documentation subject to the agreed project scope.<br \/>\n<strong>Installation Requirements:<\/strong> Final selection must consider rack heat load, power supply, unit dimensions, outdoor-unit installation and environmental conditions.<\/div>\n<\/p><\/div>\n<\/section>\n<p><!-- OPTIONAL CONFIGURATIONS --><\/p>\n<section class=\"deckro-options\" style=\"padding:22px 0;border-top:1px solid #eee;\">\n<div class=\"wrap\" style=\"max-width:1200px;margin:0 auto;padding:0 16px;\">\n<h2 style=\"margin:0 0 12px;font-size:26px;\">Configuraciones opcionales<\/h2>\n<div style=\"display:grid;grid-template-columns:repeat(3,1fr);gap:14px;\">\n<div style=\"border:1px solid #eee;border-radius:14px;padding:14px;\">\n<div style=\"font-weight:800;\">Split-Type Cooling<\/div>\n<div style=\"opacity:.85;margin-top:8px;\">Separate indoor and outdoor units available in 3.5, 7.5 and 12.5 kW configurations.<\/div>\n<\/p><\/div>\n<div style=\"border:1px solid #eee;border-radius:14px;padding:14px;\">\n<div style=\"font-weight:800;\">Integrated Cooling<\/div>\n<div style=\"opacity:.85;margin-top:8px;\">Compact 3.5 kW integrated model without a separate outdoor unit.<\/div>\n<\/p><\/div>\n<div style=\"border:1px solid #eee;border-radius:14px;padding:14px;\">\n<div style=\"font-weight:800;\">Optional Humidification<\/div>\n<div style=\"opacity:.85;margin-top:8px;\">Humidification options for split-type models, with capacities from 0.6 to 1.5 kg\/h depending on the selected model.<\/div>\n<\/p><\/div>\n<div style=\"border:1px solid #eee;border-radius:14px;padding:14px;grid-column:span 2;\">\n<div style=\"font-weight:800;\">Rack &#038; System Integration<\/div>\n<div style=\"opacity:.85;margin-top:8px;\">Project-specific integration planning for Deckro server cabinets, micro data centers and edge infrastructure, subject to mechanical and thermal compatibility.<\/div>\n<\/p><\/div>\n<div style=\"border:1px solid #eee;border-radius:14px;padding:14px;\">\n<div style=\"font-weight:800;\">Remote Management Integration<\/div>\n<div style=\"opacity:.85;margin-top:8px;\">RS485-based communication integration with compatible supervisory or building management systems, subject to protocol verification.<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/section>\n<p><!-- PRODUCT CODES --><\/p>\n<section class=\"deckro-codes\" style=\"padding:26px 0;\">\n<div class=\"wrap\" style=\"max-width:1200px;margin:0 auto;padding:0 16px;\">\n<h2 style=\"margin:0 0 12px;font-size:26px;\">Product Codes<\/h2>\n<div style=\"overflow:auto;border:1px solid #eee;border-radius:14px;\">\n<table style=\"width:100%;border-collapse:collapse;min-width:860px;\">\n<thead>\n<tr style=\"background:#111;color:#fff;\">\n<th style=\"text-align:left;padding:12px;\">Stock Code<\/th>\n<th style=\"text-align:left;padding:12px;\">Product Description<\/th>\n<th style=\"text-align:left;padding:12px;\">Capacity<\/th>\n<th style=\"text-align:left;padding:12px;\">Configuration<\/th>\n<th style=\"text-align:left;padding:12px;\">Rack Height<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"border-top:1px solid #eee;\">\n<td style=\"padding:12px;\">DRC-035-S<\/td>\n<td style=\"padding:12px;\">RackCool 3.5 kW Rack-Mounted Precision Cooling<\/td>\n<td style=\"padding:12px;\">3.5 kW<\/td>\n<td style=\"padding:12px;\">Split Type<\/td>\n<td style=\"padding:12px;\">4U<\/td>\n<\/tr>\n<tr style=\"border-top:1px solid #eee;\">\n<td style=\"padding:12px;\">DRC-075-S<\/td>\n<td style=\"padding:12px;\">RackCool 7.5 kW Rack-Mounted Precision Cooling<\/td>\n<td style=\"padding:12px;\">7.5 kW<\/td>\n<td style=\"padding:12px;\">Split Type<\/td>\n<td style=\"padding:12px;\">8U<\/td>\n<\/tr>\n<tr style=\"border-top:1px solid #eee;\">\n<td style=\"padding:12px;\">DRC-125-S<\/td>\n<td style=\"padding:12px;\">RackCool 12.5 kW Rack-Mounted Precision Cooling<\/td>\n<td style=\"padding:12px;\">12.5 kW<\/td>\n<td style=\"padding:12px;\">Split Type<\/td>\n<td style=\"padding:12px;\">10U<\/td>\n<\/tr>\n<tr style=\"border-top:1px solid #eee;\">\n<td style=\"padding:12px;\">DRC-035-I<\/td>\n<td style=\"padding:12px;\">RackCool 3.5 kW Integrated Precision Cooling<\/td>\n<td style=\"padding:12px;\">3.5 kW<\/td>\n<td style=\"padding:12px;\">Integrated<\/td>\n<td style=\"padding:12px;\">8U<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<p style=\"margin:12px 0 0;opacity:.75;font-size:13px;\">*Outdoor operating temperature range and final model-specific performance conditions are subject to technical confirmation.<\/p>\n<\/p><\/div>\n<\/section>\n<p><!-- CTA --><\/p>\n<section class=\"deckro-cta\" style=\"padding:26px 0;border-top:1px solid #eee;\">\n<div class=\"wrap\" style=\"max-width:1200px;margin:0 auto;padding:0 16px;\">\n<div style=\"border-radius:16px;padding:18px;background:linear-gradient(135deg,#111,#2a2a2a);color:#fff;display:flex;align-items:center;justify-content:space-between;gap:14px;flex-wrap:wrap;\">\n<div>\n<div style=\"font-size:22px;font-weight:900;\">Need precision cooling for your server racks or edge data center?<\/div>\n<div style=\"opacity:.85;margin-top:6px;\">Tell us your rack heat load, available rack space and installation requirements. We&#8217;ll help you select the right Deckro RackCool configuration.<\/div>\n<\/p><\/div>\n<div style=\"display:flex;gap:10px;flex-wrap:wrap;\"><a style=\"background:#c00;color:#fff;padding:12px 16px;border-radius:10px;text-decoration:none;font-weight:800;\" href=\"mailto:sales@deckro.net?subject=Deckro%20RackCool%20Quotation%20Request\">Contact Sales<\/a><br \/>\n<a style=\"background:#fff;color:#111;padding:12px 16px;border-radius:10px;text-decoration:none;font-weight:800;\" href=\"mailto:sales@deckro.net?subject=Deckro%20RackCool%20Datasheet%20Request\">Request Datasheet<\/a><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<h1 style=\"margin: 0 0 12px; font-size: 40px; line-height: 1.1;\">Deckro RackCool Precision Cooling Systems<\/h1>\n<p style=\"margin: 0 0 18px; font-size: 18px; opacity: .85;\">Compact rack-mounted precision cooling solutions designed for efficient thermal management of server cabinets, edge data centers, telecommunications equipment and mission-critical IT infrastructure. Available in split-type and integrated configurations, RackCool delivers close-coupled cooling with intelligent inverter technology, precise temperature control and remote monitoring capabilities.<\/p>\n<div style=\"display: flex; flex-wrap: wrap; gap: 10px; margin: 0 0 18px;\">\n<p><span style=\"padding: 8px 10px; border: 1px solid #ddd; border-radius: 999px; font-weight: 600;\">3.5 \/ 7.5 \/ 12.5 kW<\/span><\/p>\n<p><span style=\"padding: 8px 10px; border: 1px solid #ddd; border-radius: 999px; font-weight: 600;\">4U \u2013 10U Rack Mounted<\/span><\/p>\n<p><span style=\"padding: 8px 10px; border: 1px solid #ddd; border-radius: 999px; font-weight: 600;\">Split &#038; Integrated<\/span><\/p>\n<p><span style=\"padding: 8px 10px; border: 1px solid #ddd; border-radius: 999px; font-weight: 600;\">DC Inverter \u2022 EC Fan<\/span><\/p>\n<p><span style=\"padding: 8px 10px; border: 1px solid #ddd; border-radius: 999px; font-weight: 600;\">RS485 Remote Monitoring<\/span><\/p>\n<\/div>\n<div style=\"display: flex; gap: 12px; flex-wrap: wrap;\">\n<p><a style=\"background: #c00; color: #fff; padding: 12px 16px; border-radius: 10px; text-decoration: none; font-weight: bold;\" href=\"mailto:sales@deckro.net?subject=RackCool%20Quotation%20Request\">Request a Quote<\/a><\/p>\n<p><a style=\"background: #111; color: #fff; padding: 12px 16px; border-radius: 10px; text-decoration: none; font-weight: bold;\" href=\"mailto:sales@deckro.net?subject=RackCool%20Technical%20Datasheet%20Request\">Request Datasheet<\/a><\/p>\n<\/div>\n","protected":false},"featured_media":99718,"template":"","meta":{"_acf_changed":false,"_monsterinsights_skip_tracking":false},"product_brand":[],"product_cat":[1218],"product_tag":[],"class_list":["post-99736","product","type-product","status-publish","has-post-thumbnail","product_cat-rackcool","description-off","first","instock","shipping-taxable","product-type-simple"],"acf":[],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/www.deckro.net\/es\/wp-json\/wp\/v2\/product\/99736","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deckro.net\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.deckro.net\/es\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":1,"href":"https:\/\/www.deckro.net\/es\/wp-json\/wp\/v2\/product\/99736\/revisions"}],"predecessor-version":[{"id":99773,"href":"https:\/\/www.deckro.net\/es\/wp-json\/wp\/v2\/product\/99736\/revisions\/99773"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.deckro.net\/es\/wp-json\/wp\/v2\/media\/99718"}],"wp:attachment":[{"href":"https:\/\/www.deckro.net\/es\/wp-json\/wp\/v2\/media?parent=99736"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.deckro.net\/es\/wp-json\/wp\/v2\/product_brand?post=99736"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.deckro.net\/es\/wp-json\/wp\/v2\/product_cat?post=99736"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.deckro.net\/es\/wp-json\/wp\/v2\/product_tag?post=99736"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}